DP3CH3641; DP3CH Series,3 Ton,13.4 SEER2

DP3CH3641
$ 2,509.33

Packaged Air Conditioner 13.4 SEER1

  • Characteristics
  • Technical Data

Standard Features

• Energy-efficient compressor with internal relief valve

• Multi-Speed ECM indoor blower motor

• Quiet horizontal discharge

• All-aluminum evaporator coil

• Copper tube / aluminum fin condenser coil

• Totally enclosed, permanently lubricated condenser fan motor

• Fully charged R-410A system

• 5 kW to 20 kW electric heat kit available as a field-installed option

• AHRI Certified; ETL listed

  DP3CH2441** DP3CH3041** DP3CH3641** DP3CH4241** DP3CH4841** DP3CH6041**
Cooling Capacity            
Total BTU/h 22,800 28,400 35,600 40,000 46,000 56,000
Sensible BTU/h 18,582 22,550 27,732 30,960 36,616 39,984
SEER2 / EER2 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6 13.4 / 10.6
AHRI Numbers 208842373 208842383 208842373 208842373 208842373 208842373
Evaporator Motor            
Type ECM ECM ECM ECM ECM ECM
Wheel (D x W) 10 x 8 10 x 8 10 x 8 10 x 8 10 x 8 11 x 8
Cooling CFM3 875 1,050 1,200 1,300 1,600 1,600
Fan-Only CFM 800 950 1,100 1,200 1,400 1,400
No. of Speeds 5 5 5 5 5 Variable
Horsepower- RPM ½- 1050 ½- 1050 ½- 1050 ½- 1050 ¾- 1050 ¾- 1050
Evaporator Coil            
Face Area (ft2) 5.26 5.25 5.25 6.2 6.2 7
Rows Deep 3 3 3 4 4 4
Fins per Inch 14 16 14 14 14 14
Metering Device Type Piston Piston Piston Piston Piston TXV
Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" ¾"
Refrigerant Charge (oz.) 51 50 57 78 87 103
Condenser Fan            
Horsepower- RPM 1/6- 810 1/6- 815 ¼- 830 ¼- 1075 ¼- 1075 ¼- 1075
Fan Diameter 22 22 22 22 22 22
# of Fan Blades 3 3 3 4 4 4
Condenser Fan Coil            
Face Area (ft2) 9.2855 12.3 12.3 16 19.5 17
Rows Deep 1 1 1 1 2 2
Fins per Inch 27 26 26 28 28 28
Metering Device Type 27 26 26 28 28 28
Compressor 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Two
Quantity / Type / Stage
Sound Power
76

76

78

78

80

80
dBA
Electrical Data            
Compressor RLA/LRA 8.4/38 13.5/72.5 16.7 / 79 17.9 / 112 19.9 / 109 26.4 / 134
Voltage/Phase (60 Hz) 208-230 / 1 208-230 / 1 208-230 / 1 208-230 / 1 208-230 / 1 208-230 / 1
Indoor Blower FLA 3.8 3.8 3.8 5.4 5.4 5.4
Outdoor Fan RLA/LRA 0.95 0.95 1.3 1.4 1.4 1.4
M.C.A.1 14.4 21.6 24.4 29.2 31.7 35.4
M.O.P.2 20 35 35 45 50 50
Operating Weights (lbs) 315 315 375 375 375 400
Shipping Weights (lbs) 324 324 387 387 387 412
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
2 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.