DX5SEA3610; DX5SE Series, 3 tons, Up to

DX5SEA3610
$ 1,771.02

Split System Air Conditioner Up to 15.2 SEER2 3 tons

  • Characteristics
  • Technical Data

Standard Features

• High-efficiency Copeland® scroll compressor

• Advanced Copeland® CoreSense™ Technology

• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T

• High-density foam compressor sound blanket

• Factory-installed filter drier

• High- and low-pressure switches

• Service valves with sweat connections and easy access to gauge ports

• Fully charged for 15’ of tubing length

• AHRI Certified; ETL Listed

  DX5SEA 1810A* DX5SEA 2410A* DX5SEA 3010A* DX5SEA 3610A* DX5SEA 4210A* DX5SEA 4810A* DX5SEA 6010A*
Cooling Capacity
Nominal Cooling (BTU/h)
Decibels (dBA)

18,000
71

24,000
72

30,000
71

36,000
74

42,000
71

48,000
72

60,000
75
Compressor
RLA LRA
Stage
Type
9.0
42.6
Single Scroll
11.5
59.5
Single Scroll
12.8
65
Single Scroll
14.1
87.4
Single Scroll
177
110.2
Single Scroll
19.9
110
Single Scroll
23.7
151
Two Scroll
Condenser Fan Motor
Motor Type
Horsepower
FLA
PSC
1/8
0.70
PSC
1/6
0.95
PSC
1/6
0.95
PSC
1/6
0.95
PSC
1/4
1.30
PSC
1/4
1.30
ECM
1/3
2.80
Refrigeration System
Refrigerant Line Size¹
Liquid Line Size (“O.D.)
Suction Line Size (“O.D.)
Refrigerant Connection Size
Liquid Valve Size (“O.D.)
Suction Valve Size (“O.D.)
2, 3
Valve Connection Type
Refrigerant Charge
  4
⅜"
¾"

⅜"
¾"
Sweat
64
⅜"
¾"

⅜"
¾"
Sweat
72
⅜"
¾"

⅜"
⅞"
Sweat
101
⅜"
⅞"

⅜"
⅞"
Sweat
102
⅜"
1⅛"

⅜"
⅞"
Sweat
177
⅜"
1⅛"

⅜"
⅞"
Sweat
180
⅜"
1⅛"

⅜"
⅞"
Sweat
209
Eletrical Data
Voltage (60 Hz)
Minimum Circuit Ampacity
5
Max. Overcurrent Protection 6
Min / Max Volts
Electrical Conduit Size

208/230-1
11.9
20
197/253
½" or ¾"

208/230-1
15.3
25
197/253
½" or ¾"

208/230-1
17.0
25
197/253
½" or ¾"
208/230-1
18.6
30
197/253
½" or ¾"
208/230-1
23.4
40
197/253
½" or ¾"
208/230-1
26.2
45
197/253
½" or ¾"
208/230-1
32.4
50
197/253
½" or ¾"
Unit Weights
Equipment Weight
Shipping Weight

126
144

151
169

202
224

202
224

260
282

260
282

283
305
Energy Star® Certified
 
   
 
 
   
 
 
   
 
 
   
 
 
   
 
 
   
 
 
   
 
¹   Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide.
²   Installer will need to supply ¾” to ⅞” adapters for suction line connections.
³   Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
4   Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions.
5   Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
6   Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
•     Always check the S&R plate for electrical data on the unit being installed.
Energy Star Notes
Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combina- tions certified to meet ENERGY STAR requirements.