DX9VCA4810; DX9VC Inverter Series, 3 ton

DX9VCA4810
$ 3,607.76

High-Efficiency, up to 22.5 SEER2, Communicating, Variable-Speed, Inverter Driven Split System Air Conditioner 4 tons

  • Characteristics
  • Technical Data

 Standard Features

• Daikin variable-speed swing and scroll compressors

• High-density compressor sound blanket

• Compatible with Daikin One+ smart thermostat and other Daikin communicating equipment

• Daikin control algorithmic logic

• In communicating mode, only two low-voltage wires to outdoor unit required

• Diagnostic indicator lights, seven-segment LED display, and fault code storage

• Daikin Inside intelligence for diagnostics

• Field-selectable boost mode increases compressor speed during unusually high loads

• Quiet DC outdoor fan motor

• Field-installed bi-flow filter drier

• Coil and ambient temperature sensors

• Suction pressure transducer

• Sweat connection service valves with easy access to gauge ports

• AHRI Certified; ETL Listed

  DX9VCA 2410A* DX9VCA 3610A* DX9VCA 4810A* DX9VCA 6010A*
Capacity and Ratings  22,600 32,800 45,000 52,000
Max. Cooling (BTU/h)
Compressor        
Type Swing Swing Swing Scroll
RLA 12.7 18.1 27.6 28.6
Condenser Fan Motor        
Horsepower (HP) ½ ½ ½ ½
FLA 2.5 2.5 2.5 2.5
Refrigeration System        
Refrigerant Line Size1        
Liquid Line Size (“O.D.) ⅜" ⅜” ⅜” ⅜”
Suction Line Size (“O.D.) ¾" ⅞” 1⅛" 1⅛”
Refrigerant Connection Size        
Liquid Valve Size (“O.D.) ⅜” ⅜” ⅜” ⅜”
Suction Valve Size (“O.D.) ¾" ⅞” ⅞” ⅞”
Valve Connection Type Front-Seated Front-Seated Ball Valve Ball Valve
Refrigerant Charge (oz.) 152 154 246 246
Superheat at Service Valve 7-9°F 7-9°F 7-9°F 7-9°F
Subcooling at Service Valve 7-9°F 7-9°F 7-9°F 7-9°F
Electrical Data        
Voltage-Phase (60 Hz) 208-230/1 208-230/1 208-230/1 208-230/1
Minimum Circuit Ampacity 2 15.2 20.6 30.1 31.1
Max. Overcurrent Protection 3 20 25 35 35
Min / Max Volts 197/253 197/253 197/253 197/253
Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Equipment Weight (lbs) 210 221 321 321
Ship Weight (lbs) 241 253 353 353
ENERGY STAR® Certified ^
^  Energy Star Notes
•     Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.
•     The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements.
1     Tested and rated in accordance with AHRI Standard 210/240
2     Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
3     Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
•     Always check the S&R plate for electrical data on the unit being installed.
•     Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
•     Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.