DX13SN0601; DX13SN Series, 5 tons, Up to

DX13SN0601
$ 1,471.09

Energy-Efficient Split System Air Conditioner Up to 14.5 SEER 5 tons

  • Características
  • Datos Técnicos
  • Dimensiones

Standard Features

• Energy-efficient compressor

• Single-speed PSC condenser fan motor

• Factory-installed filter drier

• Copper tube/aluminum fin coil

• Service valves with sweat connections and easy-access gauge ports

• AHRI Certified; ETL Listed

    DX13SN 0181A* DX13SN 0241A* DX13SN 0241B* DX13SN 0301A* DX13SN 0361A* DX13SN 0421A* DX13SN 0481A* DX13SN 0601A* DX13SN 0611A*  
  Capacities
Nominal Cooling (BTU/h)
Decibels

18,000
75

24,000
71

23,000
75

28,400
73

33,600
74

40,000
75

46,000
76

57,000
77

56,500
77
 
  Compressor
RLA LRA

9.0
48

13.5
58.3

7.7
37

12.8
64

14.1
77

17.9
112

19.9
109

25.0
134

26.4
134
 
  Condenser Fan Motor
Horsepower
FLA

1/8
0.7

1/8
0.7

1/8
0.65

1/8
0.65

1/4
1.2

1/4
1.2

1/4
1.2

1/4
1.2

1/4
1.3
 
  Refrigeration System
Refrigerant Line Size
   Liquid Line Size (“O.D.)
   Suction Line Size (“O.D.)
Refrigerant Connection Size
   Liquid Valve Size (“O.D.)
   Suction Valve Size (“O.D.) ⁴ ⁵
Valve Type
Refrigerant Charge (oz.)
Shipped with Orifice Size (in.)

⅜"
¾"


⅜"
¾"
Sweat
69
0.051

⅜"
¾"


⅜"
¾"
Sweat
64
0.055

⅜"
¾"


⅜"
¾"
Sweat
60
0.055

⅜"
¾"


⅜"
¾"
Sweat
60
0.061

⅜"
⅞"


⅜"
¾"

Sweat
62
0.070

⅜"
1⅛"


⅜"
⅞"

Sweat
80
0.076

⅜"
1⅛"


⅜"
⅞"

Sweat
91
0.080

⅜"
1⅛"


⅜"
⅞"

Sweat
94
0.086

⅜"
1⅛”


⅜"
⅞"

Sweat
111
0.086
 
  Electrical Data
Voltage/ Phase (60 Hz)
Minimum Circuit Ampacity ²
Max. Overcurrent Protection ³
Min / Max Volts
Electrical Conduit Size

208-230/ 1
12
20 amps 197/253
½" or ¾"

208-230/ 1
17.6
30 amps 197/253
½" or ¾"

208-230/ 1
10.3
15 amps 197/253
½" or ¾"

208-230/ 1
16.7
25 amps 197/253
½" or ¾"

208-230/ 1
18.8
30 amps 197/253
½" or ¾"

208-230/ 1
23.6
40 amps 197/253
½" or ¾"

208-230/ 1
26.1
45 amps 197/253
½" or ¾"

208-230/ 1
32.5
50 amps 197/253
½" or ¾"

208-230/ 1
34.3
60 amps 197/253
½" or ¾"
 
  Ship Weight (lbs) 117 120 120 132 135 189 193 202 233  
¹    Line sizes denoted for 25’ line sets, tested and rated in accordance with AHRI Standard 210/240. For other line-set lengths or sizes, refer to the installation & Operat- ing instructions and/or the long line-set guidelines.
²    Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes
³    Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
⁴    Installer will need to supply ¾” to ⅞” adapters for suction line connections.
⁵    Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
Notes
•     Always check the S&R plate for electrical data on the unit being installed.
•     Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.