Split System Air Conditioner Up to 15.2 SEER2 5 tons
Standard Features
• High-efficiency Copeland® scroll compressor
• Advanced Copeland® CoreSense™ Technology
• Copper tube/enhanced aluminum fin coil -5mm diameter on 1.5-3.0T
• High-density foam compressor sound blanket
• Factory-installed filter drier
• High- and low-pressure switches
• Service valves with sweat connections and easy access to gauge ports
• Fully charged for 15’ of tubing length
• AHRI Certified; ETL Listed
DX5SEA 1810A* | DX5SEA 2410A* | DX5SEA 3010A* | DX5SEA 3610A* | DX5SEA 4210A* | DX5SEA 4810A* | DX5SEA 6010A* | ||||||||||||||||||||||||||||||||||||
Cooling Capacity Nominal Cooling (BTU/h) Decibels (dBA) |
18,000 71 |
24,000 72 |
30,000 71 |
36,000 74 |
42,000 71 |
48,000 72 |
60,000 75 |
|||||||||||||||||||||||||||||||||||
Compressor RLA LRA Stage Type |
9.0 42.6 Single Scroll |
11.5 59.5 Single Scroll |
12.8 65 Single Scroll |
14.1 87.4 Single Scroll |
177 110.2 Single Scroll |
19.9 110 Single Scroll |
23.7 151 Two Scroll |
|||||||||||||||||||||||||||||||||||
Condenser Fan Motor Motor Type Horsepower FLA |
PSC 1/8 0.70 |
PSC 1/6 0.95 |
PSC 1/6 0.95 |
PSC 1/6 0.95 |
PSC 1/4 1.30 |
PSC 1/4 1.30 |
ECM 1/3 2.80 |
|||||||||||||||||||||||||||||||||||
Refrigeration System Refrigerant Line Size¹ Liquid Line Size (“O.D.) Suction Line Size (“O.D.) Refrigerant Connection Size Liquid Valve Size (“O.D.) Suction Valve Size (“O.D.) 2, 3 Valve Connection Type Refrigerant Charge 4 |
⅜" ¾" ⅜" ¾" Sweat 64 |
⅜" ¾" ⅜" ¾" Sweat 72 |
⅜" ¾" ⅜" ⅞" Sweat 101 |
⅜" ⅞" ⅜" ⅞" Sweat 102 |
⅜" 1⅛" ⅜" ⅞" Sweat 177 |
⅜" 1⅛" ⅜" ⅞" Sweat 180 |
⅜" 1⅛" ⅜" ⅞" Sweat 209 |
|||||||||||||||||||||||||||||||||||
Eletrical Data Voltage (60 Hz) Minimum Circuit Ampacity 5 Max. Overcurrent Protection 6 Min / Max Volts Electrical Conduit Size |
208/230-1 11.9 20 197/253 ½" or ¾" |
208/230-1 15.3 25 197/253 ½" or ¾" |
208/230-1 17.0 25 197/253 ½" or ¾" |
208/230-1 18.6 30 197/253 ½" or ¾" |
208/230-1 23.4 40 197/253 ½" or ¾" |
208/230-1 26.2 45 197/253 ½" or ¾" |
208/230-1 32.4 50 197/253 ½" or ¾" |
|||||||||||||||||||||||||||||||||||
Unit Weights Equipment Weight Shipping Weight |
126 144 |
151 169 |
202 224 |
202 224 |
260 282 |
260 282 |
283 305 |
|||||||||||||||||||||||||||||||||||
Energy Star® Certified |
|
|
|
|
|
|
|
|||||||||||||||||||||||||||||||||||
¹ Line sizes denoted for 25’ line sets, tested and rated in accordance with ARI Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide. ² Installer will need to supply ¾” to ⅞” adapters for suction line connections. ³ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. 4 Unit is factory charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions. 5 Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes. 6 Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combina- tions certified to meet ENERGY STAR requirements. |